Door or Gate Control Basics
Door control contacts are provided from the Doorphone Controller and are
typically used for door strike activation or gate control. For security, the door
control relay is located in the Controller to avoid entry by tampering. The Door
Station dry contact output (OUT) may be congured for ‘low security’ gate
control requiring a low current dry contact.
Door Release
Door release typically involves energizing or de-energizing a door strike which
pivots to allow a locked door to open without retraction of the latch bolt. There
are two different types of door strikes:
“Fail Locked” (or “Fail Secure”)
“Fail Unlocked” (or “Fail Safe”)
24V 0.3A
Door
Strike
“Fail Locked”
24 Vdc 0.2 A Typical
24V 0.3A
“Fail Unlocked”
24 Vdc 0.2 A Typical
Fail Locked / Fail Secure Electric Strike
These require power to release and
remain locked during power failure. The
door may still normally be opened from the
outside with a key, or from inside without
a key. The door control relay is used to
apply power to release the door.
Fail Unlocked / Fail Safe Electric Strike
These (as well as magnetic locks), require
power to lock and become unlocked
during power failure. The door control
relay is used to maintain power to the
door lock (NC and C contacts) which is
interrupted to release the door. Magnetic
locks may require override systems to
allow safety exit in the event of re.